| Technical Characteristics |
|
- Intervention distances adjustable:
- from 4 m to 20 m (RDM/20);
- from 5 m to 30 m (RDM/30);
- from 5 m to 60 m (RDM/60);
- from 5 m to 99 m (RDM/99)
- Digital setting of distance in metres. Measurement resolution: 1 metre, with indication independent of environmental and ageing-related factors.
- Digital indication of the distance in metres via luminous display in cabin.
- Acoustic signalling of slowing and stopping (optional, via Mod. RDM-RC repeater).
- Directivity superior to any other system currently on the market (-3 dB at 3°).
- Minimal power density of emitted signal: 3,5µW/cm2 in contact with the parabola.
- No danger to people or objects (limit of Osha=1 mW/cm2).
- Easy alignment of the reflector with the transmitter, guided by LED indicators located both on the display unit and on the parabola.
- Unaffected by normal bridge-crane skew.
- Unaffected by variations in power supply voltage of +15/-20% at constant rate.
- Unaffected by sudden variations in power supply voltage due to spikes up to - 40%.
- Measurement unaffected by rising hot air currents, vibrations, humidity, rain or dust.
- Autodiagnosis of transmitter group, receiver, frequency modulator, quartz time base and power supply; any failure is signalled by dropout of the stop relay.
- No preventive maintenance.
- All operations controlled by a microcomputer.
- Anti-interference filter between conductors and earth for voltages up to 3 kV for 500 µs or 1500 V 50 Hz for 3 s.
- Electronics unit in IP55 container.
- Operating voltage: 110 V 50/60 Hz; 220 V 50/60 Hz on request.
- Operating temperature: -15 ÷ +70°C.
- Absorbed power: 25 VA.
- Relay current-carrying capacity: 10 A 250 Vca.
- Complies with CE and international regulations regarding electrical safety and electromagnetic compatibility (EMC).
- Unrestricted-use transceiver equipment (ERC/REC 70-03E).
|
|
|
|
|
CEIA SpA
|
|
Costruzioni Elettroniche Industriali Automatismi
Zona Industriale Viciomaggio 52041 Arezzo - Italy
Tel. +39 0575 4181 Fax +39 0575 418296
qa-detectors@ceia-spa.com
VAT number IT00308150515
| | CEIA USA West Coast Office | Mr. Alen Tucker
Tel. +1 916 436 1205 Tel. +1 440 991 6842 Fax +1 503 665 1951
atucker@ceia-usa.com
| |
|
|
|