  • Automatic inspection of parcels and letters up to 45 cm in width and 7.5 cm thickness
  • Detection of detonators, batteries, trigger circuits and other metal components of parcel bombs
  • No alarm on metal staples, paper-clips and metal binding spirals
  • Confirmation of signal (OK/ALARM) for each package inspected
  • Ergonomic, compact design
  • Operates on the mains power supply and with built-in NiMH rechargeable batteries
  • Integrated battery charger
  • No calibration or periodic maintenance required
  • Optional embedded detector of radioactive materials

Brochures
Click To View GB Brochure
Click To View F Brochure
Click To View I Brochure
Click To View D Brochure
Click To View JP Brochure



Manuals

EMIS-MAIL

Letter Bomb and IED Detector for mail & parcel inspection.

Description

EMIS-MAIL - detail

Easy installation and use

The EMIS-MAIL is designed to detect a wide variety of metal threat items including detonators, batteries, trigger circuits and other metal components of parcel bombs without false alarms for non-threat items such as metal staples, paper clips and metal binding spirals.

The EMIS-MAIL is very easy to use and provides a fast and automatic alarm/no alarm signal confirmation per each inspected package. Its compact, ergonomic design along with the electric and built-in NiMH rechargeable battery power supply allows for independent operation in a variety of locations. An optional embedded radioactive detector is also available for radioactive material threat detection.

The EMIS-MAIL is uniquely qualified to operate in a prison or correctional facility environment with specific settings available for prison parcel inspection. Along with meeting the strictest safety and security standards, EMIS-MAIL is also compliant with the EU Regulation 185/2010 for the inspection of letters and parcels.

Key features of the CEIA EMIS-MAIL include:

  • Ease of Installation and Setup
  • Ease and Speed of System Use with Limited Screener Training Required
  • Automatic Inspection of Parcels and Letters up to 450 mm x 75 mm
  • No Calibration or Periodic Maintenance Required
  • Independent Operation with Mains Power Supply or Built-in NiMH Rechargeable Batteries

Specifications

General characteristics

  • High inspection speed
  • No alarm on metal staples, paper-clips and metal binding spirals
  • Very high discrimination of paper-clips, metal staples and binding spirals
  • Digital programming with high-resolution OLED graphic display
  • Optical and acoustic alarm signalling
  • Integrated autodiagnosis system
  • Permanent memory storage of operating parameters without back-up batteries
  • Independent operation, with mains power supply or incorporated batteries
  • Specific Settings available for Prison parcels inspection (Dept. of Justice applications)
  • Compliant with NIJ-0602.02 Dept. of Justice Detection requirements
Structure
  • Transit opening 450 mm x 75 mm
  • Degree of protection IP40
Weight
  • 16 kg
Power supply
  • Voltage 100-240 V~ single-phase – 50-60 Hz with external AC/DC adapter
  • Current 1.07 A max
  • Battery operation
    • 6 x 1.2V NiMH size D incorporated
    • Battery life: 12 hours
    • Battery-charger incorporated: Recharging time 6 hours
      • Programming
        • Type
          • Local: via integrated keypad
          • Remote: via Bluetooth, RS232
        • Memory capacity: 10.000 events
        Signalling
        • Acoustic: Internal buzzer
        • Optical
          • High-contrast OLED graphic display with bar-graph indication
          • LED indicators on the control panel
            • RED: Alarm, Autodiagnosis
            • GREEN: OK, Power supply
            • BLUE: Alarm, detection of radioactive substances
        Security/safety
        • Access to programming protected by password
        • Galvanic insulation from mains voltage
        Communication
        • Incorporated Bluetooth interface, RS232
        Environmental data
        • Operating Temperature: -10 to +50 °C
        • Storage Temperature: -25 to +60 °C
        • Relative humidity: 5 to 90 %, without condensation
        Conformity (Test Reports available upon request)
        • Safety
          • EN61010-1 Safety requirements for electrical equipment for measurement, control and laboratory use - Part 1: General requirements
        • EMC
          • EN61000-6-1:2007 Electromagnetic Compatibility (EMC) – Part 6-1: Generic standards – Immunity for residential, commercial and light-industrial environments
          • EN61000-6-3:2007 Electromagnetic Compatibility(EMC) – Part 6-4: Generic standards – Emission standard esidential, commercial and light-industrial environments
          • European Directive 2004/108/CE
        NATO stock number
        • 6665150105807

    Applications

    Options

    Accessories

    Documents


    Brochures
    Click To View GB Brochure
    Click To View F Brochure
    Click To View I Brochure
    Click To View D Brochure
    Click To View JP Brochure



    Manuals



    Certificates
    CE Certificate
    Human Exposure Certificate



    Technical Drawings
    Technical Drawings