| Key features | 
- Integrated Type B and Type A Standard 3 certified System
 - Automatic inspection of any type of containers
 - Inspection time in ~ 5 seconds (type B) and ~ 4 seconds (type A)
 - Multiple simultaneous sensing technologies
 - Minimum installation space
 - Minimum operator training required
 - All solid state
- No mechanical parts in movements
 - No-ionizing or laser sources
 
  - No maintenance required
 
  | 
| Multiple sensing technology | 
- Wideband Radio Frequency (R.F.)
 - Infrared (IR)
 - Magnetic Inductive
 - Gravimetric
 
  | 
| Inspection Characteristics | 
- Commercial Bottles of any shape and materials including plastic, glass, metal with capacity ranging from 100 ml to 2000 ml
 - Type A sample cups volume: 10 ml
 - Initial Start-up time: 15 sec. max
 - Analysis type: automatic
 - Analysis time: 5 sec. typical (type B) and 4 sec. typical (type A)
 
  | 
| Detectable substances | 
- Explosive precursors and explosive liquids
 
  | 
| Alarm Signalling | 
 
 | Light color | Display message | Meaning |  | Green | OK | Allowed liquid |  | Yellow | Not allowed product | Alarm of medium intensity |  | Red | Not allowed product | Alarm of high intensity |  
 
 
  | 
| Acoustic alarm | 
| Threat classification available | 
| Operator interface | 
- Easy to read high-contrast graphic display
 - High durability stainless steel function keys
 - Programmability of all the parameters protected by passwords
 
  | 
| Function and calibration control | 
- Automatic calibration, continuously running
 - Manual verification of calibration, performed by the operator through Pass/No-Pass reference test pieces (according to the operational procedures)
 
  | 
| Communication capability | 
- RS-232 serial interface
 - Ethernet network interface
 
  | 
| Remote control and Ethernet Networking Functions | 
- Available through the CEIA NetID Management software
- Programming
 - Statistical Data Collection
 - Maintenance
 - Firmware upgrade
 
  
  | 
| Degree of protection | 
 | 
| Weight | 
- 17 kg (type B only)
 - 17.5 kg (type B and type A)
 
  | 
| Main Electronics Features | 
- High integration SMT
 - 32-bit flash-based microcontrollers
 - 32-bit DSP
 - Low power and high reliability
 - Very low power inspection field, confined in the analysis compartment, completely safe for both the operator and the liquid
 - No ionizing radiation or radioactive sources
 - No laser sources
 
  | 
| Main Mechanical Features | 
- Constructed entirely in AISI304 Stainless Steel
 - Anti-fingerprint surface treatment
 - Rugged and Durable
 - Compact and Aesthetically pleasing
 
  | 
| Installation and Maintenance | 
- Automatic adjustment to environmental conditions
 - No initial or periodic calibrations required
 - Firmware upgradeable via RS232 or Ethernet interface
 - No periodical maintenance or consumables required
 - Built-in automatic calibration and self-diagnosis system
 
  | 
| Certification and conformity | 
- Standard 3 Certified according to ECAC performance requirements for Type B Liquid Explosive Detection Systems
 - Standard 3 Certified according to ECAC performance requirements for Type A Liquid Explosive Detection Systems
 - Conforms to the currently applicable International Standards for Electrical Safety and EMC
 
  | 
| Power Supply | 
- 115/230V~ ±15%, 50/60 Hz ±10%, 15W
 
  | 
| Environmental conditions | 
- Operating temperature: 0°C to +40°C
 - Storage temperature: -10°C to +60°C
 - Operating Relative humidity: 0 to 95% (without condensation)
 - Storage Relative humidity: 0-98%, without condensation
 
  | 
| NATO Stock Number | 
- 6665-151805235
 - 6665-151805236
 
  | 
| Type A analyser (optional) |